| Performance/Scalability/Flexibility |
- 1 PA-8900 processors-800 MHz with 1.5 MB L1 cache/64 MB L2 cache (rp3410); 1 or 2 PA-8900 processors-800 MHz and 1.0 GHz with 1.5 MB L1 cache/64 MB L2 cache (rp3440)
- 6 GB memory capacity (rp3410); 32 GB memory capacity (rp3440)
- 2 PCI-X I/O card slots (rp3410); 4 PCI-X I/O card slots (rp3440)
- 1.5 GB/s aggregate I/O slot bandwidth (rp3410); 2.5 GB/s aggregate I/O slot bandwidth (rp3440)
- Rack and standalone server solutions
- 1 internal removable media bay (DVD-ROM or DVD+RW)
- Hot-swap, redundant power supplies
- Redundant (N+1) input power
- Hot-swap, redundant cooling fans
|
| Operating system |
HP-UX 11i v1, HP-UX 11i v2, and HP-UX 11i v3 |
| Availability |
- Dynamic CPU and memory allocation/de-allocation
- Memory chip-sparing technology
- Error checking and correction (ECC) on all CPU, cache, memory, and I/O paths
- Online addition and replacement of PCI I/O cards
- Redundant power inputs for dual grid connections
- N+1 hot-swappable fans and power supplies
|
| Optional high-availability and business-continuity solutions |
- HP Serviceguard for HP-UX 11i
- HP Serviceguard Extension for RAC for HP-UX 11i
- HP Serviceguard Extension for SAP for HP-UX 11i
- HA Monitors for for HP-UX 11i
- Event Monitoring Service
- HP Serviceguard Manager for HP-UX 11i
- High Availability toolkits for HP-UX 11i
- HP Mirrordisk/UX for HP-UX 11i
- HP Extended Campus Cluster HP-UX 11i
- HP Extended Campus Cluster for RAC HP-UX 11i
- HP Metrocluster with EMC SRDF for HP-UX 11i
- HP Continentalclusters (including RAC) for HP-UX 11i
- Comprehensive mission-critical services and support
|
| Connectivity |
- Core I/O: 10/100/1000Base-T LAN, Ultra160 SCSI, management LAN, 3 serial ports
- Add-in cards: See Options & Accessories
|
| Manageability |
Central point of management-HP Systems Insight Manager provides a single point of administration and integrates the following tools for configuration, fault and workload management:
- Configuration management
-HP Ignite-UX for installation and deployment of the operating system -HP Software Distributor-UX for software and patch management -HP System Administration Manager for HP-UX system administration -WBEM for consistent management
- Fault management
-HP Event Monitoring Service for fault management -Management Processor for comprehensive remote server management of HP-UX
- Workload management
-HP-UX Kernel Configuration for easy, dynamic kernel parameter changes -HP Process Resource Manager for HP-UX resource management (optional) -HP-UX Workload Manager for workload management based upon prioritized service-level objectives (optional)
|
| Investment protection and flexibility |
- Chassis designed for future generations of PA-RISC
- In-box upgradeability to Intel Itanium processors
|
| Support and services |
- Analysis, design, and implementation of infrastructure, IT processes, and IT organization
- Educational services
- Smart Set integration services
- Implementation services
- Proactive and reactive support services
- Outsourcing and business recovery services
- Financial services
|
| Rack-optimized design |
- Rackmount solution offering allows server to fit into 2U (8.6 cm height) space in all HP racks (Rack System/E and 10000 series rack)
- AB241A: HP rack kit for HP 9000 rp3400 Series Servers
- AB242A: HP pedestal kit for HP 9000 rp3400 Series Servers
For a complete list of racks and rack accessories, refer to http://h18004.www1.hp.com/products/servers/proliantstorage/bcs-rackandpower/index.html |
| Physical and environmental specifications |
| Physical dimensions |
| Height |
3.4 in. (86 mm); 2U EIA |
| Width |
19 in. (482 mm) |
| Depth |
26.8 in. (680 mm) |
|
| Physical dimensions (standalone) |
| Height |
19.5 in. (495 mm) |
| Width |
11.6 in. (295 mm) |
| Depth |
26.6 in. (675 mm) |
|
| Net weight |
| Maximum configuration |
56 lb. (25 kg) |
|
| Temperature |
| Operating |
+41° to +95° F (+5° to +35° C) |
| Non-operating |
-40° to +158° F (-40° C to +70° C) |
| Maximum rate of temperature change |
18° F (10° C) per hr with tape media, 36° F (20° C) per hr without tape media |
|
| Humidity |
| Operating |
15% to 80% relative |
|
| Altitude |
| Maximum operating |
10,000 ft. (3000 m) |
| Maximum non-operating |
15,000 ft. (4500 m) |
|
| Power requirements |
| Input current |
100-127 V ~8.0 |
| Line frequency |
50-60 Hz |
| Maximum power input |
714 W |
|
| Power supply |
|