| Performance/Scalability/Flexibility |
- Up to 16 dual core HP PA-RISC PA-8900 processors
- PA-8900 (1.068 GHz with 3MB L1 cache/64 MB combined L2 cache)
- 1 to 4 cell boards (each cell can accommodate up to 4P/8C and up to 64 GB of memory)
- 2 to 256 GB memory capacity per system
- 16 PCI-X internal hot-plug I/O card slots
- 4 internal disk bays and 2 internal removable media bays (DVD + RW or DAT)
- Optional Server Expansion Unit 2 (SEU-2)
16 additional PCI-X hot-plug I/O card slots 4 additional disk drive slots 2 additional removable media slots (DVD + RW or DAT)
- Up to 2 hard partitions (nPars); up to 4 hardware partitions with optional SEU-2
- Support for up to 16 virtual partitions (vPars); up to 32 virtual partitions with optional SEU
- 138.4 GB/s Peak crossbar bandwidth and 23 GB/s aggregate I/O slot bandwidth (46 GB/s using SEU-2)
- Hot-swap, redundant power supplies
- Redundant (2N+1) input power
- Hot-swap, redundant cooling fans
|
| Operating system |
HP-UX 11i v1, v2, v3 (choice of Foundation,Enterprise, Mission-Critical, and Technical Computing operating environments). |
| Availability |
- Dynamic CPU and memory allocation/de-allocation
- Hot-plug cell boards
- Hot-plug fans
- Error checking and correcting (ECC) on all CPU, cache, memory, and I/O paths
- Online addition and replacement of PCI I/O cards
- Redundant power inputs for dual-grid connections
- Redundant clock sources
- Management processor failover (core I/O)
- N+1 hot-swappable fans and power supplies
- Hot-spare Instant Capacity CPU functionality (requires Instant Capacity CPUs)
- Hardware partitions (nPars)
|
| Connectivity |
- Core I/O:
- 10/100/1000Base-T LAN
- Ultra320 SCSI
- Management LAN
- 1 RS-232 serial port for local console
- Add-in cards: Various Networking (Ethernet), storage (Fibre Channel, SCSI), network/storage combo and specialized IO cards
|
| Investment protection and flexibility |
- Utility pricing - Pay per use, Instant Capacity, and Pay per forecast
- Temporary Instant Capacity
- Cell Instant Capacity
- Easy in-box upgrade to HP Integrity
- Interchangeable components with other HP servers and storage solutions
- HP-UX 11i OS binary, source, and data compatibility
|
| Manageability |
HP Management solutions deliver the software and services needed to manage today's most demanding IT environments. These solutions help your organization reduce operational costs, increase staff efficiencies, improve application availability and optimize service delivery.
» Learn More
|
| Optional High Availability and Business Continuity solutions |
HP High Availability & Business Continuity solutions help reduce operational risk, enhance IT performance and develop stable, reliable and agile enterprises.
- Business Continuity
- High Availability Management
- Disaster Tolerance
- Data Protection and Recovery
- Security
» Learn more |
| Rack-optimized design |
- Rackmount solution offering allows server to fit into 10U (44.45 cm height) space in all HP racks (Rack System/E and 10000 series rack)
- J1530B: HP field rack kit
- J1530BZ: HP factory rack kit
For a complete list of racks and rack accessories, refer to http://h18004.www1.hp.com/products/servers/proliantstorage/bcs-rackandpower/index.html
|
| Physical and environmental specifications |
| Physical dimensions |
| Height |
Racked chassis: 29.75 in. (756 mm); 17U EIA Standalone chassis: 32.8 in. (833 mm) Server expansion unit: 15.75 in. (400 mm); 9U EIA |
| Width |
19 in. (482 mm) |
| Depth |
30 in. (762 mm) |
|
| Net weight |
| Maximum configuration Chassis: |
378 lb. (171.4 kg) Server expansion unit: 180 lb. (81.65 kg) |
|
| Temperature |
| Operating |
+41° to +89° F (+5° to +32° C); 86° F (30° C) @ 10,000 ft. (3000 m) |
| Non-operating |
-40° to +158° F (-40° to +70° C) |
| Maximum rate of temperature change |
36° F (20° C) per hr |
|
| Humidity |
| Operating |
15% to 80% RH non-condensing |
|
| Altitude |
| Maximum operating |
10,000 ft. (3000 m) |
| Maximum non-operating |
15,000 ft. (4500 m) |
|
| Power requirements |
| Typical power dissipation |
3,789VA (max. configuration) 18.95 A @ 200 V |
|
| Regulatory |
| Safety |
UL listed, CUL certified, TÜV GS Mark, compliant with EN 60950 |
| Electromagnetic interference |
Complies with FCC rules and regulations, Part 15 as a Class A Digital Device; Manufacturer's Declaration to EN55022 Level A, VCCI |
| Power line LF emissions |
Registered, Class I, Korea RLL Europe: EN 61000-3-2; Europe: EN 61000-3-3 |
|